Advanced Medical Waste Incineration in South Sudan: Why HICLOVER TS200 PLC is the Perfect Fit
In South Sudan, the safe and efficient disposal of medical and hazardous waste is a growing challenge, particularly in hospitals, refugee camps, and remote health facilities. Meeting strict international technical requirements while also adapting to local conditions is crucial.
The HICLOVER TS200 PLC incinerator is specially designed to address these challenges, offering industrial-grade performance, intelligent control, and reliable compliance.
Below, we explore how the TS200 PLC aligns with customer technical requirements, using real data and our expert answers.
Technical Requirements
CE or FDA compliant
Yes – TS200 PLC carries CE certification (2006/42/EC, 2014/30/EU) and ISO9001:2015.
It is produced under certified quality control, ensuring full compliance for international projects.
FIREPLACE: Fully insulated internal refractory lining
Instead of a simple confirmation, our product features:
-
High alumina refractory brick (≥115 mm thick, composition ≥65% Al₂O₃, 1750°C grade) for both primary and secondary chambers.
-
Additional high-rate refractory ceramic fiber cold face layer.
-
Heavy-duty refractory with steel fiber on other hot face parts for extra durability.
This advanced multi-layer design ensures superior insulation, heat retention, and long operational life.
Combustion chamber volume
Instead of a generic “yes,” the TS200 PLC offers:
-
Primary chamber volume: 1980 liters (1.98 m³).
-
Secondary chamber volume: 800 liters (0.8 m³).
Designed for an average burn rate of 180 kg/hour and feed capacity of 200–250 kg per feeding, ideal for medium to large facilities.
External metal sheet: Anti-corrosion paint
We apply 250°C grade heat-resistant paint on the external steel surfaces, effectively protecting the incinerator against rust and tropical humidity typical in South Sudan.
Temperature indicator
Beyond a simple “yes,” our model includes:
-
Corundum probe tube thermometer rated up to 1600°C.
-
Continuous temperature display via 3.7-inch LCD screen.
-
Automatic temperature protection and alarms.
High temperature retention (HTR)
The TS200 PLC includes an automatic HTR system with temperature adjustability to keep:
-
1st chamber: 800–1000°C.
-
2nd chamber: 1000–1300°C.
Residency time of 2 seconds in the secondary chamber ensures full combustion of harmful substances.
PLC Automatic control
Our model uses a full PLC automatic system, supporting:
-
Intelligent sensor safety system.
-
Automatic burner on/off control.
-
Automatic cooling and false alarm alerts (visual/audio/display).
-
System testing mode and programmable time settings.
-
Intelligent fuel-saving function to reduce running costs.
Burner brand
We use Italy brand burners, ensuring long service life, automatic ignition, and high combustion efficiency.
Fuel consumption
-
Diesel oil consumption: Approx. 22 kg/hour.
-
Natural gas consumption: Approx. 25 m³n/hour.
Efficient design helps reduce fuel costs, critical in areas with limited fuel supply.
Electrical system
-
Voltage: Standard 220V (with wet scrubber, 380V).
-
Power: 2.0 kW (8 kW if wet scrubber is installed).
The low power requirement means the incinerator is compatible with local grids or diesel generators.
Loading system
Default:
-
Manual top loading door (1300x1000mm).
Optional: -
Front or side loading doors to fit different site designs.
The top-loading design is ideal for handling bulky waste like medical gowns, packaging, and containers.
Automatic system: Fuel-saving & protection
We offer:
-
Automatic high temperature retention.
-
Automatic fuel-saving mode.
-
Automatic cooling and shutdown.
-
Alarm systems (display/voice/light) for temperature or system faults.
Chimney
-
Stainless steel chimney, height 8 meters.
-
Refractory lined section (1 meter) at the base to protect against high temperatures.
Designed to withstand harsh outdoor conditions.
Certifications & quality
-
CE (2006/42/EC, 2014/30/EU).
-
ISO9001:2015.
-
Recognized as a High-tech Enterprise.
Fully documented for international tenders and donor-funded projects.
Optional upgrades
-
Wet scrubber: For gas cleaning and lower emissions.
-
Containerized mobile design: Perfect for camps or remote facilities.
Why TS200 PLC Matches South Sudan’s Needs
-
Large capacity: Supports high daily waste volumes.
-
Intelligent PLC control: Safe and easy to operate, even with limited skilled labor.
-
Low power consumption: Works with local power conditions.
-
Fuel flexibility: Runs on diesel or natural gas.
-
Compact footprint: Fits urban hospitals or rural clinics.
-
Optional containerized/mobile: Quick deployment for emergency or field hospitals.
Reliable Support for Critical Projects
From large urban hospitals in Juba to humanitarian camps in the north, the HICLOVER TS200 PLC is ready to serve South Sudan’s public health and environmental goals.
Contact us for full technical details, drawings, and compliance documents:
Website: www.hiclover.com
-
South Sudan incinerator
-
medical waste incinerator
-
PLC automatic incinerator
-
HICLOVER TS200 PLC
-
containerized mobile incinerator
-
CE certified incinerator